Setting Timed Heat Up Schedule

Have more questions? Submit a request

There are 2 ways of setting this up: 1. Via the Curv Smart App

                                                          2. Via the cylinder display.

1.Via the Curv Smart App

  • Open the Curv Smart App
  • Select the Cylinder
  • Under SETTINGS select CURRENT MODE
  • Select ECO
  • Set the Workday (Mon-Fri) time intervals max 2 interval
  • Set the Rest day (Sat-Sun) time intervals maximum of 2

    The start and end tomes must be different otherwise the setting is invalid i.e. 00:00 - 00:00 the schedule will not heat up.

  • Press CONFIRM to store this setting

2. Via the Display

L1 & L2 refer to Work days (Mon-Fri) and L3 & L4 refer to Rest days (Sat-Sun) just like on the app.

  • On the display press MODE until ECO  is displayed.
  • Press SET on the display to take you to the Time Schedule.
  • L1 will appear and the Start Time press the + & - to adjust the Hour press SET
  • Adjust the Minutes with the + & - press SET 
  • Do the Same for L2, L3, L4 press SET a final time to store the program.

    Caution: this will not re heat the cylinder outside of these time schedules