AUTO MODE - Optimised Management of the heat pump and the electrics for guaranteed comfort:
- Priority for Heat pump use
- If Compressor works for more than 20Hrs, Unit automatically switches on auxiliary power.
- Unit Automatically Re-heats when Set point temperature drops by 10°C this ensures hot water is readily available.
ECO(OFF-PEAK) MODE - User can set the time periods so that the unit does not work outside of these times.
- After selecting the ECO Mode
Press SET to enter up to 4 time ranges L1 & L2 time ranges are for Monday-Friday & the L3 & L4 are for Saturday & Sunday time ranges, the start and end time must be different otherwise the time period is invalid
CYLINDER WILL NOT RE-HEAT OUTSIDE THESE TIME PERIODS AND MAY LEAD TO LACK OF STORED HOT WATER!
ELECTRIC HEATING MODE - Electric elements is used to heat the water instead of the heat pump.
- This function should be activated if there is an issue with the heat pump operation to ensure Hot water supply.
VACATION/HOLIDAY MODE - This mode will disable the heat up of the cylinder for a set period of days.
- set the number of vac/holiday days from 1-99 days, for example if you leave home on the 1st Jan and return on the 5th Jan the number of days should be set to 5 days.
- The day before the Vacation/holiday the cylinder will heat up according to the sterilization program.
BOOST MODE - This mode is required if a quicker heat up time is needed.
- Press the Boost button on the cylinder display.
This activates both the heat pump and the electric element to reduce the heat recovery time of the cylinder. Caution this consumes more power so may lead to higher electricity costs.